Link485 Air

Wi-Fi Modbus Gateway

★★★★★ (4.8/5 from 38 reviews)

Link485 Air bridges your RS-485 Modbus devices to Wi-Fi networks, enabling cloud integration, mobile apps, and modern IoT platforms. Convert Modbus RTU to Modbus TCP, MQTT, or HTTP/REST APIs with an easy-to-use web configuration interface.

📶
Wi-Fi Ready 2.4 GHz 802.11 b/g/n
☁️
Cloud Integration MQTT, HTTP, Modbus TCP
🌐
Web Configuration Browser-based setup
Link485 Air Wi-Fi Modbus Gateway

Key Features

1x Modbus RTU Interface

Connect legacy Modbus RTU devices (RS-485) to Ethernet networks and enable remote access via Modbus TCP protocol.

2x 5A Relay Outputs

Control equipment directly with two built-in 5A relays for automated control based on Modbus data or schedules.

Wi-Fi Connectivity

2.4 GHz 802.11 b/g/n Wi-Fi radio for wireless connection to existing networks. Supports MQTT, HTTP REST API, and Modbus TCP.

Bluetooth Low Energy (BLE)

Built-in BLE radio for local configuration, diagnostics, and mobile app connectivity without network access.

Technical Specifications

Modbus Interface

Ports1x Modbus RTU (RS-485)
Baud Rate1200 - 115200 bps
Termination120Ω switchable

Relays & I/O

Relay Outputs2x 5A (NO/NC)
Rating250V AC / 30V DC
ControlModbus, schedule, cloud

Wireless

WiFi1x 802.11 b/g/n 2.4GHz
BLE1x Bluetooth Low Energy
SecurityWPA2-PSK, WPA3

Protocols

Modbus TCPClient/Server
MQTTv3.1.1, TLS 1.2
HTTP/HTTPSREST API

Power & Physical

Input Voltage12-24V DC
Operating Temp-20°C to +70°C
MountingDIN rail 35mm

Perfect For

🏨

Building Automation

Connect HVAC, lighting, and energy meters to Wi-Fi for centralized monitoring and control.

📊

Data Logging

Stream sensor data to cloud databases, time-series platforms, or analytics systems.

🏭

Factory Monitoring

Connect production machines to MES/SCADA systems via Wi-Fi without additional wiring.

Energy Management

Monitor power meters and integrate with energy management systems via MQTT or REST API.

Frequently Asked Questions

Yes! Link485 Air supports WPA2-Enterprise authentication (802.1X) for corporate WiFi networks with RADIUS servers. It also works with guest networks and can handle captive portals in most cases.

Link485 Air uses WPA2/WPA3 encryption for WiFi. All cloud communication uses TLS/SSL encryption. The web configuration interface supports HTTPS. You can also configure VPN tunneling for additional security.

Link485 Air automatically reconnects when WiFi becomes available. It buffers Modbus data locally during disconnections (up to 1000 transactions). You'll receive alerts via SMS/email if the connection stays down for more than configured threshold (default 5 minutes).

Yes! Link485 Air works perfectly on local WiFi networks without internet. You can use Modbus TCP mode to communicate with local SCADA/BMS systems. Internet is only required if you want to use Link485 Cloud features or send data to external services.

Link485 Air supports up to 32 Modbus slave devices on the RS-485 bus. Polling rate depends on your requirements - typical installations poll 10-20 devices every 1-5 seconds without issues.